Language
CN EN
微信图片_20240418164053
智能实验室一站式扶植交付
已成功实施客户案例工程超过2万平
Automatic Fiber Dissolver
Consultation message
图片1
Automatic Fiber Dissolver

Fully automatic fiber dissolution instrument adopts advanced technologies such as filter bagbatch technology with invention patent, automatic control, human-machine interaction, specialanti-corrosion materials, etc., to realize the automation of chemical dissolution test process. Theinstrument automatically adds dissolving reagents, soaks the sample, dynamically and accuratelycontrols the temperature, visualizes the dissolution process, classifies the waste, and cleans anddehydrates, saving more than 90% of the workload of quantitative analysis. The testing processincludes automatic process control such as liquid addition, rotation, waste collection, waterwashing, neutralization of residual liquid, washing again, dehydration, etc., which realizes one.button start, unattended operation, uniform operation of the dissolution and washing processbetter dissolution effect than manual differentiation, good data stability, high replaceability ofpersonnel, and low training cost.




Product Specification /Technical Data
ModelFQLB-RJ1800 (2nd gen)Effective capacity3000ml
Motor speed0-800r/minBatch volume50 specimens
Repeatabilityaccuracy≤1%SafetyEnclosed operation, off-handwork
Liquid fillingaccuracy±0.5mlConsumablesOuantitative filter bags
EnvironmentneedsNormal temperature andhumidityTemperature rangeRoom temperature to 959C;Temperature control accuracy:±0.1°C.
Working ModeCustomize the test program, the whole automatic operation, test processvisualization.
SpecificitySpecialized quantitative filter bag for the whole process of dissolution,filtration, cleaning and dehydration of specimens. The whole processeliminates the manual repetition of adding liquid, pumping filtration,cleaning and other work, which is both safe and efficient.
StandardGB/T 2910、1S0 1833、FZ/T01026-2017、FZT 01095-2002、JIS L1030-2、AATCC 20A、(EU)1007/2011 etc.
The test results & accuracy after dissolution are the same as the conventional methodand reduce the labor time by more than 85%;Using the 75% sulfuric acid method, which is the most commonly used method, thefollowing is a comparison of the results of random sample dissolution test data:



Specimen numberColorFabric NameConventional MethodsTest ResultsInstrument Dissolution Test Results
1CT-R2164511Navy blueKnitted double-sided fabric

78.0%cotton 

22.0%polyester

78.2%cotton 

21.8%polyester

2XT-R114232103

Rice-white

Knitted velvet

73.0%cotton

27.0%polyester

73.0%cotton 

27.0%polyester

3XT-F113132711

Bnight white

Ribbed cloth

67.0%cotton

33.0%polyester

67.0%cotton 

33.0%polyester

4CT-R2122181Grayish blueDouble jerseyfabric

88.1%cotton

11.9%polyester

88.1%cotton 

11.9%polyester

5CT-R2147383面料Rusty redDouble jerseyfabric

79.8%polyester

20.2%cotton

79.5%polyester 

20.5%cotton

6CT-R2147383帽里Rusty redSingle jerseyfabric

83.8%polyester

16.2%cotton

83.7%polyester 

16.3%cotton

7CT-R2137886BlackKnitted double-sided fabric

79.4%cotton

20.6%polyester

79,3%cotton 

20.7%polyester

8CT-R2169519pinkJersey fabric

65.2%cotton

34.8%polyester

65.3%cotton 

34.7%polyester

9CT-R2166531Rice-white

Woven bubole Wrap

59.9%cotton

40.1%polyester

59.5%cotton 

40.5%polyester

10CT-R2148187 liningBlack

Woven bubole Wrap

79.8%polyester

20.2%cotton

79.9%polyester 

20.1%cotton




Get more professional consultations for free
Please select a province
Beijing
Tianjin
Hebei
Shanxi
Inner Mongolia
Liaoning
Jilin
Heilongjiang
Shanghai
Jiangsu
Zhejiang
Anhui
Fujian
Jiangxi
Shandong
Henan
Hubei
Hunan
Guangdong
Guangxi
Hainan
Chongqing
Sichuan
Guizhou
Yunnan
Xizang
Shaanxi
Gansu
Qinghai
Ningxia
Xinjiang
Taiwan
Hong Kong
Macao
test
Please select a city